Menu

Your patients all have a different CRRT requirement

Their needs should dictate their treatment

Target their recovery Individualise their therapy

Increased modality choice with a citrate based anticoagulant, coupled with the ability to swap between heparin and citrate utilising the same line set are key highlights of . Whilst maintaining the automatic titration, unique fluid balance auto-compensation, familiar interface and easy trouble-shooting as appreciated on the original AquariusTM.

Highlights

  • Choose a pure convective therapy with post or pre-dilution
  • Choose a pure diffusive therapy with citrate anticoagulation
  • Choose citrate and / or heparin anticoagulation with one line set
  • Individualise your citrate prescription based on patient requirements
  • Automatically titrates citrate dose based on blood pump speed
  • Choose adult RCA or heparin capability with no recalibration
  • Choose extended set-life capability – up to 100 hours

Treatment CVVH – post-dilution

Citrate solution is infused into the blood circuit before the blood pump. To compensate for the amount of Calcium lost in the filtrate, Calcium solution is infused into the blood circuit just before the air detector system and after the drip chamber.

Treatment CVVH – pre-dilution

Citrate containing replacement solution is infused into the blood circuit after the blood pump and before the hemofilter. Calcium solution is infused into the blood circuit just before the air detector system and after the drip chamber.

Consumables for the AquariusTM system with RCA (GE-F095-00)

The AquariusTM system with RCA system provides complete prescription flexibility with one Aqualine RCA for all therapies, regardless of anticoagulant choice. Regular Aqualine can also be used with the AquariusTM system with RCA for treatments without citrate anticoagulation.

Products CITRASET RCA 12 CITRASET RCA 19
Aquamax ® filter HF12 HF19
Bloodline Aqualine RCA Aqualine RCA
Bloodline blood volume 100 ml 100 ml
Ancillaries 1 effluent bag 5 liter + 1 empty priming bag 2 liter + 1 two-way connector

Technical Data

Flow rates ADULT
Blood pump TPE
CVVH
30 to 250 ml / min
30 to 300 ml / min
Post-dilution pump TPE
CVVH
0 or 500 to 3,000 ml / h
0 or 500 to 6,000 ml / h
Citrate pump 0 to 650 ml / h
Calcium pump 0 or 2 to 300 ml / h
Fluid loss CVVH 0 to 2,000 ml / h
Scales
Citrate / Calcium maximum load 2.2 kg
Citrate and Calcium intended use in CVVH Post-dilution
Concentration of citrate between 110 mmol / l and 150 mmol / l
Concentration of calcium supplementation approx. 5 mmol / l to 20 mmol / l

CRRT (Continuous Renal Replacement Therapy), CVVH (Continuous Veno-Venous Hemofiltration) and TPE (Therapeutic Plasma Exchange).